40kw Brushless Three Phase Alternator

Product Details
Customization: Available
Conditions
of Use:
Connect with Diesel Engine
Usage: Land Use
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 13 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (28)
  • 40kw Brushless Three Phase Alternator
  • 40kw Brushless Three Phase Alternator
  • 40kw Brushless Three Phase Alternator
  • 40kw Brushless Three Phase Alternator
  • 40kw Brushless Three Phase Alternator
  • 40kw Brushless Three Phase Alternator
Find Similar Products

Basic Info.

Model NO.
JET224D
Output Type
AC Single Phase
Cooling
Method
Air Cooled
Installation
Method
Fixed
Generator
Type
Brush / Brushless Type Alternator
Insulation Class
H Class
Alternator Type
Brushless Synchronous Alternator
Rotor and Stator
100% Copper Wire
Rated Speed
1500rpm / 1800rpm
Protection Class
IP21 / IP23
Generator Warranty
1 Year or 1000 Working Hours
Manufacturing Standard
GB755, Part 3 of BS5000, VDE0530, Ute5100, NEMA
Coil Winding
2/3 Pitch Winding Design
Frequency
50Hz / 60Hz
Excitation Type
Brushless Self-Excitation with AVR
Transport Package
Plywood Case
Specification
6.5KW to 1100KW Stamford type alternator
Trademark
JET POWER
Origin
China
HS Code
8502110000
Production Capacity
1000

Product Description

Detailed description
1.Brushless synchronous alternator with Stamford technology.
2.Output range:6.5kw - 1150kw single-phase and three-phase
3.High-performance Convenient installation and maintenance 
4.Three phase 4 wire, optional 50Hz/60Hz, 1500/1800RPM
5.4-pole, brushless alternator with AVR, H class insulation, IP21
6. Be suitable for various brands engine, international standard SAE port, double bearing as optional
Specifications:
 
MODEL 3-PHASE 50Hz /1500RPM 380V-440V 3-PHASE 60Hz /1800RPM 440V-480V DIMENSION WEIGHT
(KVA) (KW) (KVA) (KW) CM KG
JET 164A 8.1 6.5 10.2 8.2 64×54×72 95
JET 164B 11 8.8 13.8 11 64×54×72 102
JET 164C 13.5 10.8 16.9 13.5 64×54×72 110
JET 164D 16 12.8 20 16 64×54×72 116
JET 184E 22.5 18 28.8 23 84×59×75 133
JET 184F 27.5 22 34.4 27.5 84×59×75 156
JET 184G 31.3 25 37.5 30 84×59×75 172
JET 184H 37.5 30 46.9 37.5 84×59×75 226
JET 184J 40 32 50 40 84×59×75 236
JET 224C 42.5 34 52.5 42 96×66×102 275
JET 224D 50 40 62.5 50 96×66×102 295
JET 224E 60 48 70 56 96×66×102 315
JET 224F 72.5 58 87.5 70 96×66×102 345
JET 224G 85 68 97.5 78 96×66×102 385
JET 274C 100 80 118 94 126×76×102 415
JET 274D 114 91 138 110 126×76×102 435
JET 274E 140 112 168 134 126×76×102 485
JET 274F 160 128 190 152 126×76×102 530
JET 274G 175 140 213 170 126×76×102 580
JET 274H 200 160 245 196 126×76×102 630
JET 274J 230 184 281 224.8 130×76×102 750
JET 274K 250 200 299 239.2 130×76×102 760
JET 444C 250 200 294 235 151×79×107 880
JET 444D 295 236 350 280 151×79×107 950
JET 444E 325 260 394 315 151×79×107 1065
JET 444FS 380 304 456 365 151×79×107 1145
JET 444F 400 320 480 384 151×79×107 1185
JET 544C 450 360 550 440 165×95×116 1350
JET 544D 500 400 594 475 165×95×116 1450
JET 544E 600 480 713 570 165×95×116 1700
JET 544FS 625 500 725 580 165×95×116 1753
JET 544F 670 536 775 620 165×95×116 1820
JET 634B 750 600 855 684 180×100×145 2020
JET 634C 800 640 916 732.8 180×100×145 2050
JET 634D 910 728 1034 834.2 180×100×145 2100
JET 634E 1000 800 1145 916 180×100×145 2260
JET 634F 1130 904 1274 1019.2 180×100×145 2490
JET 634G 1250 1000 1386 1108.8 180×100×145 2820

JET Series Brushless Synchronous Alternator are made adopted Stamford alternators technology and according to the standards of GB755,IEC60034,NEMA etc. The alternators have standard features: voltage adjust, stability adjust, under frequency roll off, over exciting protection, low radio interference, etc. The stators are 2/3 pitch winding, the rotors are fixed sequential damper winding. The stator core is designed landler taking advantage of CAD, ensuring a very low waveform distortion. "H" class insulation system is provided the high build required for static windings and the high mechanical strength required for rotating components.
Alternator Features:
 
1)Advanced automatic voltage regulator control for trouble-free operation under the most demanding condition
2)Easy paralleling with mains or other generators .Standard 2/3 pitch windings avoid excessive neutral currents. 
3) Dynamically balanced rotor, with sealed-for-life ball bearings and single or two-bearing construction.
4)Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts.
5)Wide range of Flange adaptor and single bearing coupling disc.
 
MECHANICAL FEATURES
 
Voltage regulation
 
Voltage regulation refers to the change of voltage from no-load to full-load with power factor ranging from 0.5 to 1 and 2.8%s fluctuation of the speed of engine. Voltage is adjusted via potentiometer of AVR, model: SX460, SX440
 
Axis and Key
 
All of alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1,G 2.5 two bearing alternator has a half-key testing balance
 
Terminal and terminal box
 
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non drive end . The box is equipped with removable panels.
 
 
ELECTRIC FEATURES
Insulation Class H
 
All regulatory components are made up with special materials and are immersed in lacquer by peculiar tech. Vanish and colophony materials are develop to strengthen the processing and machinery intensity of windings and revolving parts for protecting the alternator work under corrosive environment.
 
Winding and electric features
 
2/3 pith winding design can effectively eliminate the third harmonic wave(3th.9th,15th) of the voltage ,which is the best design of UPS for nonlinear load .Connected with the network in parallel, the structure can restrain excessive currents in the midline. This and the 2/3 pitch help to check the wave distortion and output voltage.
 
Phone interference and Radio interference
 
THF (defined by 40thpart of BS4999) <2%.TIF<50
Brushless apparatus and quality AVR ensure little radio interference in transmission. RFI noise filter is also available.
 
Accessories & Option
 
Droop kit for sharing of reactive current during parallel operation
Remote voltage potentiometer
PT100 thermal protection embedded in stator windings
Anti condensation heaters
IP23 protection
Special treatment for damp-saline or corrosive Environment
PMG
Control panel with LCD digital meter
 
Manufacturing Standard
 
GB755, PART 3 of BS5000, VDE0530, UTE5100, NEMA MG1-22, CEMA, IEC34-1, CSA22.2 and AS1359.
 
Warranty policy
 
JET product has guarantee for one year or 1200 hours whichever reach first from ex-factory date. During the guarantee period, our will provide the free easy-damageable spare parts of alternator caused by our quality of production or raw material. After expiration, our provides cost spare parts maintenance of alternator.
 
40kw Brushless Three Phase Alternator

40kw Brushless Three Phase Alternator
40kw Brushless Three Phase Alternator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier